Heat
How hot did it get?
91.2°C
Peak recorded temperature in antigen retrieval, 3.8 °C under the protocol’s 95 °C. Measured at the slide.
When a stain is questioned, pull up the slide’s history: the heat, time and handling your patients’ tissue went through, from water bath to scan.

Illustrative case
A question for your lab
Not the setpoint. Not the run. Slide S1-0264.
Where would you look for the answer today?
The answer
91.2°C.
3.8 °C under the protocol’s 95 °C
In this example the HER2 protocol called for 36 minutes at 95 °C. The run finished, and the report showed the protocol.
The slide recorded what it reached in that step: a peak of 91.2 °C, 3.8 °C short.
One slide, three answers
Heat
91.2°C
Peak recorded temperature in antigen retrieval, 3.8 °C under the protocol’s 95 °C. Measured at the slide.
Time
55min
Mounted at 09:08, on the stainer at 10:03. Well inside the six weeks ASCO/CAP guidance gives a cut HER2 section.2
Handling
2.4g
Peak recorded acceleration, at 13:56. Operator note: rack set down before coverslipping.
Heat, time and handling, kept with the one slide they happened to.
Illustrative record excerpt · S1-0264
Free, with no obligation to order. Or order V1 and get an S1 demo kit.
Images, reports, LIS fields and instrument logs tell part of the story. S1 adds the slide’s own record of temperature, elapsed time and handling.
A protocol says what should happen. S1 records what did, at the slide, on every run.
Inside S1
Sensors sealed inside the label end. The record stays with the slide from water bath to scan. Tap your phone to read it.
01Handling
0.19g
Steady. Peak over the last 30 minutes, on three axes.
02Temperature
60.0°C
In spec, 58 to 62 °C. 1.0 °C spread across three sensor points.
03Record
214entries
Append-only. Slide S1-0264. Stored on the slide, read with a compatible phone.
04Time
00:19:41
Step 3 of 7, drying. Every reading carries its own timestamp.
Once the slide is stained, its history is gone. S1 keeps it.
Illustrative values. Not yet for sale. In development.
Recording starts. S1-0264, case P-2048.
38 s on the water. Three serial sections, one ribbon.
30 min, upright, nothing touching the sections.
12 min on the bench at 22.4 °C. 55 min since the section mounted.
First puddle, sealed under liquid coverslip.
The run finished and the report showed the protocol. The slide recorded what it reached, minute by minute.
HER2 primary antibody, 12 min.
The chromogen develops on the cores, nowhere else.
Every step of the run, timed and on the record.
after 1 h 27 min in the queue · 2.4 g at 13:56, rack set down
on the record · 214 entries · ready to read with a tap
The Prova Record™
Every S1 read can be exported as a Prova Record: one document your QA lead can open, review and keep.
Reviewer’s note · Antigen retrieval 10:31 to 11:07
Stain repeated on a new section. Slide position held for a heat check.
J. Smith, Histology Supervisor
Reviewed 14:32
Slide ID, case and assay, carried on every page of the record.
Start time, duration and the temperature measured at the slide.
The thresholds come from your lab’s settings, and the record shows which were crossed.
Movement and acceleration events, each with the time it happened.
The reviewer’s name and note, attributed and time-stamped. What happens next stays your lab’s call.
New readings are appended to the on-slide record. Existing readings stay as they were recorded.
From slide to file
One slide. One day. One page your QA lead will want to read.
Illustrative record. Final format may change.
Read it
No separate reader to buy. Read S1 with a compatible phone and the Prova mobile app: hold it to the label end and the slide’s record opens.
Recent reads
Hold the top edge of your phone against the label end. Keep it still until the read is complete.
Read S1Today
91.2°C peak
3.8 °C under the protocol’s 95 °C in antigen retrieval.
Selected steps
Where it matters most
Some results carry more weight in clinical interpretation. Those are the workflows to record first.
HER2, 0 or 1+
In 2023, ASCO and CAP called the distinction between HER2 IHC 0 and 1+ clinically relevant.2 A 2022 study of CAP survey data and a separate reader cohort reported low agreement at that same boundary.3
The call rests on faint, partial membrane staining, where small differences in a run can matter.
S1 recordsRetrieval heat and time, at the slide
An equivocal IHC result can lead to reflex ISH testing, with its own denaturation and hybridization steps.
S1 recordsDenaturation and hybridization, start to finish
A small focus on a needle core is often confirmed on a single stained slide.
S1 recordsThe whole day of that one slide
The PathVysion protocol sets denaturation at 72 °C, give or take one degree, before hybridization.4
S1 recordsTemperature and time through denaturation
S1 doesn’t score a stain. It shows whether the slide had the day its protocol called for.
Also on the list: ER and PR, Ki-67, PD-L1, mismatch repair. Sources: Wolff AC et al., J Clin Oncol 2023; Fernandez AI et al., JAMA Oncol 2022; Abbott PathVysion package insert. Full references below.
Serial sections
These sections came from one block and followed different workflows, as IHC and ISH should. Each record shows the temperature and timing of its own journey, including how long each stayed in the dryer.
Same block, same morning, adjacent sections.
Different protocols by design, and different waits by circumstance.
Each slide brings its own record to the review.
Every S1 adds to your lab’s record. It builds with every run, and it is evidence that images and logs can’t supply.
Built for the lab you already run
S1 keeps the standard 75 × 25 mm footprint and is designed for the baths, dryers, stainers, coverslippers and scanners you already use.
Flotation bath
Leica HI1210
Slide dryer
Thermo Scientific Heratherm
Stainer
Roche BenchMark ULTRA PLUS
Coverslipper
Leica CV5030
Scanner
Leica Aperio GT 450
One format. Many workflows.
Leica BOND‑PRIME
Leica BOND‑MAX
Agilent Dako Autostainer Link 48
Biocare ONCORE Pro
Epredia Lab Vision Autostainer 360
Leica HistoCore SPECTRA ST
Sakura Tissue‑Tek Prisma Plus
Leica ST5020 Multistainer
Thermo Scientific Heratherm OGS60
CellPath Mini Section Dryer
Leica Aperio GT 450
Hamamatsu NanoZoomer S360
Boekel Deluxe Lighted Tissue Flotation Bath
Leica CV5030
Roche VENTANA DP 200
3DHISTECH Pannoramic 1000
Sakura Tissue‑Tek Film
Leica IP S
Epredia SlideMate AS
Epredia E1000 Dx
Grundium Ocus 40
Leica HistoCore CHROMAX ST
StatLab PiSmart Slide Printer
Milestone PRESTO PRO
Leica BOND‑III
Agilent Dako Omnis 165 Duo
Sakura Tissue‑Tek Genie
Biocare intelliPATH+
Roche VENTANA HE 600
Leica HistoCore SPECTRA CV
Epredia Gemini AS
ZEISS Axioscan 7
CellPath High Capacity Section Dryer
Agilent Dako Artisan Link Pro
Leica Aperio AT2
Leica HistoCore Water Bath M
Epredia Digital Paraffin Flotation Bath
Philips IntelliSite SG300
Roche VENTANA DP 600
Sakura Tissue‑Tek Glas g2
Epredia ClearVue
Epredia SlideMate Laser
Primera Signature
Motic EasyScan Infinity
Huron TissueScope iQ
Leica HistoCore CHROMAX CV
Sakura Tissue‑Tek SmartWriteS1 keeps the 75 × 25 mm footprint. No platform is validated yet. Compatibility is validated platform by platform.
In the box
Thirty S1 slides inside, sealed and asleep.
Half on the mold, half on the rim. Pull both tabs.
It holds every slide still and keeps dust out on the way to your lab.
Run it along the rim. Each slide lights as its record starts.
Load them where your slides already go.
The planned 30-slide production carton. Slides stand label end up, ready to scan and lift out, like the racks you use today.
Renders. Packaging and app screens may change before release.
Quick start
Slide the box off, peel the two violet seals and lift the mold.
Open the Prova mobile app and run your phone along the rim of the tray. The app wakes each slide, and its seam lights as recording starts.
Pick up your section the way you always do. The record is already running.
Bake, stain, coverslip and scan on the instruments you use today. S1 travels with its section.
Hold the top of your phone to the label end. The slide’s whole day opens in the app.
Planned use. Steps may be refined before release.
In your space
Turn it here, or place it on your bench in AR and walk around it. Every seam lit, every slot numbered.
See it on your bench.Scan with your iPhone or Android phone to place the tray at true size.
Answers
S1 at a glance
Prova S1 is not yet for sale. In development. Planned capabilities; performance and instrument compatibility require validation.
Free reservation
Reserve S1 for your lab. It’s free, with no obligation to order. We’ll contact you before the first production run.
We’ll be in touch before the first production run.
The example. Slide S1-0264, its case, readings, limits and review notes are illustrative. They show a planned workflow, not a customer result. The protocol time and temperature follow reference 1. S1 records, app screens, values and scenarios on this page are illustrative.
The product. Prova S1 is not yet for sale. In development. Capabilities are planned, and performance and instrument compatibility require validation. Reservations are free and are not orders.
The record. S1 records processing conditions. It does not score a stain or make a diagnosis.
AR viewing needs a recent iPhone, iPad or ARCore Android device. Instrument names are trademarks of their respective owners. Prova is not affiliated with or endorsed by them.